COMMERCIAL OUTDOOR HEATER
STEP 9 - TESTING PROCEDURE FOR PROPANE
Prepare a cup of very soapy water.
Attach Regulator to your L.P. Tank. Tighten securely with a wrench or the
handwheel (if provided). Leave the L.P. Tank outside of the Cabinet for the testing
procedure.
Open the valve on the L.P. Tank. Leave the Heater Valve in the “OFF” position.
With a brush or sponge, apply the soap and water mixture liberally to the union
(junction) between the Regulator and the L.P. Tank, and the union between the
Regulator and the Valve Fitting.
Any leaks will blow soap bubbles.
Repair any and all leaks by tightening union with wrench.
Once any and all leaks have been stopped, the heater is ready for use!
DO NOT USE A FLAME
FOR LEAK TESTING
TESTING PROCEDURE FOR NATURAL GAS
Prepare a cup of very soapy water.
Attach heater gas hose to gas supply line. Tighten securely with a wrench .
Open the gas supply line valve. Leave the Heater Valve in the “OFF” position.
With a brush or sponge, apply the soap and water mixture liberally to the union
between the supply line and heater valve. Any leaks will blow soap bubbles.
Repair any and all leaks by tightening union with wrench.
Once any and all leaks have been stopped, the heater is ready for use!
DO NOT USE A FLAME
FOR LEAK TESTING